Status Monitoring
AlphaNet
IDH3
DOCSIS
®
Status Monitor
AlphaNet IDH3
Specifications
Power Supply Models
Supported:
XM2-HP, XM2
Battery Monitoring: Up to two strings of 36V or 48V batteries
Monitoring Protocol: SNMP v1
Devices Monitored:
Power Supply, Batteries and Generator
(compatible with ANSI/SCTE 25-3 2002,
formerly HMS 022)
Management Protocol:
Standard ANSI/SCTE HMS MIBs support basic
power supply monitoring.
Hardware
RF Cable Interface: F-connector, female, 75 Ohm
Local Interface:
RJ-12, RS-232, 19.2kb,N,8,1
Requires serial port adapter and
PC with terminal emulation software
(Hyper-Terminal recommended)
LED Indicators:
Transponder Ready/RF Link Established
Transponder/CMTS Communications
Power Supply/Transponder Communication
I/O Signals:
Battery, tamper, and AlphaBus interfaces located
on EDSM interface card
Environment
Operating Temperature: -40 to 65°C / -40 to 149°F
Storage Temperature: -40 to 85°C / -40 to 185°F
Humidity: 10 to 90% non-condensing
Regulatory Compliance:
EN50022 Class A and FCC Part 15 Class A
(Installed in power supply enclosure system)
Cable Modem:
Compliance: DOCSIS 1.1 and 2.0
Transmit Frequency Range: 5 to 42 Mhz
Receive Center Frequency Range: 91 to 857 Mhz
Output Power Range: 8 to 58 dBmV
Input Signal Range: -15 dBmV to 15 dBmV
Channel Bandwidth: 6 Mhz
Power Supply Monitored Parameters
Major Alarm:
Aggregate Alarm consisting of: test fail, battery
fail, line isolation alarm, output overload, inverter
over temperature, N+1 active, fuse fail
Minor Alarm:
Aggregate Alarm consisting of: temperature
probe error, AC line loss, N+1 error
Input Voltage: Reported from power supply V(in) measurement
Output Voltage: Reported from power supply V(out) measurement
Output Current 1-4:
0-25A standard on port 1. Ports 2-4 require
power supply option.
Output Power: Calculated, reported in AC Watts
UPS Status: AC line, Standby, Test in-process, Test alarm
Enclosure Door: Open/Closed
Battery Voltage:
Up to 2 battery strings
Individual battery voltages measured reported to
±100mv resolution
Battery Temperature:
Reported from power supply battery Remote
Temperature Sensor (RTS)
Remote Test Control: Start/Stop XM2 self test cycle
Generator Monitored Parameters
Status: Generator off, Running, Alarm
Generator Alarm:
Aggregate alarm consisting of: low oil pressure,
engine over-temp, engine over-speed, crank limit,
over voltage, low fuel, water intrusion, pad shear,
gas hazard, test fail
Gas Hazard: OK, Alarm
Water Intrusion: OK, Alarm
Pad Shear: OK, Alarm
Enclosure Door: Open, Alarm
Ignition Battery Voltage: +/- 100mV
Enclosure Temperature: +/- 2
°
C
Low Fuel: OK, Alarm
Remote Test: Start and Stop control input
> Alpha XM2-HP and XM2 embedded status monitoring
> Standard network interface including SNMP,
Web access and ANSI/SCTE HMS MIBs
> Monitors one or two 36V or 48V battery strings
> Used with EDSM interface card
> Optional VoIP testing features
AlphaNet IDH3