IPDP - installation and operating instructions
3.2.3 All about relays
After making changes use the save changes button.
1. Relay mode:
=1 switch mode it will close on command or password for period t1/2
(used for electrical locks, gate opening etc.)
=2 camera mode it will close by guard pick up and open by hanging up.
=3 lighting mode it will close by guard pick up and stay closed even for
period t1/2 after guard hanging up.
=4 bell mode it will close after button pressing and open after period t1/2
(used for e.g. external bell or horn connections).
=5 gradual opening mode in this mode the only relay 2 will be set
together with relay 1 set to mode 1. The relay 1 is activated for period t1,
then the time t3 is proceeding before relay 2 closing. Then the relay 2 is
activated for t2 period and afterwards the DoorPhone hangs up.
Note: The only relay 1 can be activated from phone and all sequence started.
Besides that the relay 2 can be separately activated from buttons by password.